Hired-hand Farm Hand Series: SCS w/Back-Up Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Hired-hand Farm Hand Series: SCS w/Back-Up. Hired-Hand Farm Hand Series: SCS w/Back-Up User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 25
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Part No. 4801-5117 Rev. 8-01 Owners Manual Farm Hand SCS
Farm Hand SCSFarm Hand SCS
Farm Hand SCS w/BackFarm Hand SCS w/Back--UpUp
Hired Hand, Inc.
1733 Co Rd 68
PO Box 99
Bremen, AL 35033
Vue de la page 0
1 2 3 4 5 6 ... 24 25

Résumé du contenu

Page 1 - Farm Hand SCSFarm Hand SCS

Part No. 4801-5117 Rev. 8-01 Owners Manual Farm Hand SCS Farm Hand SCSFarm Hand SCS Farm Hand SCS w/BackFarm Hand SCS w/Back--UpUp Hired Hand, Inc

Page 2 - Table of Contents

Part No. 4801-5117 Rev. 8-01 Farm Hand SCS 8 To Back-up Relay hand the Fail-Safe relay strip would close each of the relays in the strip resultin

Page 3

Part No. 4801-5117 Rev. 8-01 Farm Hand SCS 9 12. Day-to-Day Back-Up Operating Instructions 12.1 Toggle Sequence of Mode Button Continuously p

Page 4

Part No. 4801-5117 Rev. 8-01 Farm Hand SCS 10 2. Press the ”+” and ”–“ buttons to enter the value of the High Limit. 3. Setting Complete. Set

Page 5 - 5. Farm Hand SCS Panels

Part No. 4801-5117 Rev. 8-01 Farm Hand SCS 11 1. Place a thermometer inside the house at the location of each sensor. Allow a few minutes for

Page 6 - Farm Manager 16 stage SCS™

Part No. 4801-5117 Rev. 8-01 Farm Hand SCS 12 17. Wiring Diagrams Warning! Before connecting power to the machine, be sure to place the jumpers

Page 7

Part No. 4801-5117 Rev. 8-01 Farm Hand SCS 13 17.2 Setting the Back-Up Board Jumpers, Sensors and Alarm Connections

Page 8 - 8.1 Normal SCS™ Operation

Part No. 4801-5117 Rev. 8-01 Farm Hand SCS 14 17.3 16 Stage SCS™ Panel Back-Up Jumper Posi

Page 9 - Temperature (ºF)

Part No. 4801-5117 Rev. 8-01 Farm Hand SCS 15 17.4 Setting the Local Network Address DIP Switch Settings SCS™ Stage Addr

Page 10

Part No. 4801-5117 Rev. 8-01 Farm Hand SCS 16 17.5 SCS™ Local Net and Back-Up Interconnection Diagram

Page 11 - 13. Set Limits

Part No. 4801-5117 Rev. 8-01 Farm Hand SCS 17 17.6 SCS™ Connections to the Power Supply HOT 120V NEUT 240V

Page 12 - 15. Calibrate Sensors

Part No. 4801-5117 Rev. 8-01 Farm Hand SCS Table of Contents Table of Contents Section Title Page 1. Ratings and S

Page 13 - 16. Installation

Part No. 4801-5117 Rev. 8-01 Farm Hand SCS 18 17.7 SCS™ Connections to the Curtain Machine Top Left of SCS Panel POWER TRAK HO

Page 14 - Warning!

Part No. 4801-5117 Rev. 8-01 Farm Hand SCS 19 17.8 Connecting Power from Breaker to a Heat Stage or Cool Stage All wiring must meet N.E.C. and

Page 15

Part No. 4801-5117 Rev. 8-01 Farm Hand SCS 20 Note: In step 2, it very important to remove electrical power from the circuits connected to the re

Page 16 - 17.3 16 Stage SCS™ Panel

Part No. 4801-5117 Rev. 8-01 Farm Hand SCS 21 19. Temperature vs. Sensor Resistance Table The following chart gives the resistance when measur

Page 17 - 1 2 3

Part No. 4801-5117 Rev. 8-01 Farm Hand SCS 22 20. Error Codes If your controller is displaying an “E1” or “E2”, etc. the controller has recorde

Page 18

Part No. 4801-5117 Rev. 8-01 Farm Hand SCS 23 21. SCS™ Program Label Programming P 1-9 Stage Programming P1 = Metric Units P2 = Alarm On Back

Page 19 - Power Supply

Part No. 4801-5117 Rev. 8-01 Farm Hand SCS 1 1. Ratings and Specifications • 115/230 Volts (Depending on switch position.) • 50/60 Hz. • 1 h

Page 20 - CONTROLLER

Part No. 4801-5117 Rev. 8-01 Farm Hand SCS 2 4. Introduction to the SCS™(Smart Contactor System) The SCS™ (Smart Contactor System), in its simp

Page 21 - Using the SCS™ Panel

Part No. 4801-5117 Rev. 8-01 Farm Hand SCS 3 5. Farm Hand SCS Panels Farm Hand SCS 8 Sta

Page 22 - B Crider

Part No. 4801-5117 Rev. 8-01 Farm Hand SCS 4 AUTO OFF ON Stage Control Switch (3 position) Stage Status Indicators Write in the Name you choose

Page 23

Part No. 4801-5117 Rev. 8-01 Farm Hand SCS 5 6. Connecting Multiple SCS™ Panels to a Master Controller Up to 128 SCS™ stages can be controlled f

Page 24 - 20. Error Codes

Part No. 4801-5117 Rev. 8-01 Farm Hand SCS 6 DIP Switch Settings SCS™ Stage Address Assignment No. 1 No. 2 No. 3 ON ON ON 1 –16 OFF ON ON

Page 25 - Programming

Part No. 4801-5117 Rev. 8-01 Farm Hand SCS 7 it warms the building at least 2°. The same is true if the temperature goes above the High Limit ho