SENS-O-MATIC II™
Hopper Switch
HIRED-HAND, INC. 1733 County Road 68 Bremen, AL 35033 USA Phone 256-287-1000 Fax 256-287-2000
Manual Part No. 4802-0134 rev 5-07 Page 1 of 2
WARNING!
Only qualified electrician personnel familiar with the
construction and operation of this equipment and the
hazards involved should install and/or service this
equipment. It is important that all standard electrical
codes be observed when wiring the Sens-O-Matic™.
Read and understand all instructions and diagrams
before proceeding. Failure to observe this precaution
could result in equipment damage, severe bodily
injury, or loss of life.
DESCRIPTION
The Hired Hand Sens-O-Matic II™ is an electronic
feed hopper switch which turns the feed auger On or
OFF depending on the hopper feed level. A NEW
FEATURE recently added is the Push-to-Reset
Circuit Breaker. The circuit breaker is externally
accessible and has replaced the internal glass tube
fuse which required opening the enclosure. The Sens-
O-Matic™ is a direct retrofit for the standard Paddle
Switch currently used in the poultry industry. If the
feed fill system and paddle-type Hopper Switch is
controlled by 240vac, a 240vac Sens-O-Matic™ is
required. If the feed fill system and paddle-type
Hopper Switch is controlled by 120vac, a 120vac
Sens-O-Matic™ is required. Installation of the Sens-
O-Matic™ is quick and simple with only three wire
connections as shown in the wiring diagram provided
on Page 2. Approximately 3 feet of electrical cord and
a slide-in mounting tab bracket are supplied
preattached to the Sens-O-Matic™. No assembly is
required. The Sens-O-Matic™ is preset for an
approximate 30 second time-delay from an Off state to
an activated On state when nothing is sensed near the
sensing area.
When the kit is received, check for shipping damage.
Contact Hired-Hand Customer Support for information
regarding the universal mounting bracket and external
power supply options if these options are required.
Part # Description
6606-0110 SM-2-I-126S Sens-O-Matic™ 120v 60hz
6606-0114 SM-2-I-246S Sens-O-Matic™ 240v 60hz
6406-1126
/Universal Mount Bracket Assembly
6606-0112 SM-2-E-246S Sens-O-Matic™ 240v 60hz Ext Pwr Supply
6607-1598 PS-24VAC-250VA-120/240VAC Power Supply
Wire Stripper Wire Connectors
Sens-O-Matic II™
Assembly & Installation
A. Disconnect AC electrical power from all equipment.
B. Place the Sens-O-Matic™ inside the feed hopper
and slide the mounting tab into the hopper retaining
slot.
NOTE: The feed tube should not be placed to allow the
feed to dump directly onto the Sens-O-Matic™.
C. Route and secure the Sens-O-Matic™ power cord in
a safe and secure location.
D. Connect the black, white, and green wires as shown
in the wiring diagram on Page 2.
E. Ensure that all wires are secure and safely clear
from moving/turning auger components.
F. Apply power and test the Sens-O-Matic™ with feed
to ensure proper operation.
WARNING!
Remove ALL Electrical Power from the feed fill
system before installation / wiring.
Never plug the Sens-O-Matic™ into a standard 120
or 240 VAC receptacle as serious injury may result.
Figure 1: Sens-O-Matic II™ Control
Mounting Tab
PCB168
15 Amp
Push-to-Reset
Circuit Breaker
NEW
Power
Connection
* Patent Number: 5,051,671